TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 158 of 1432

YES TM 9-2320-365-20-2 2-1212 Change 1 e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT) 3. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION NO Repair or replace wire 1499D (para 2-40). 110 VAC outlets J231, J232, J233, and J234 OK. 110 VAC outlet J235 OK. Circuit breaker CB9 OK. Wire 701C OK. Wire 702C OK. Relay K35 OK. 110 VAC receptacle J230 OK. Faulty wire 1499D. Faulty wire 3085J. Faulty wire 3085AC. Is continuity present on wire 1499D from 110 VAC receptacle J230 to terminal board TB4? If continuity is not present, wire 1499D is faulty.