Change 1 2-1211 TM 9-2320-365-20-2 CONTINUITY TEST (1) Disconnect AC power (TM 9-2320- 365-10). (2) Remove screw and cover from 110 VAC outlet J230. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to supply pole of 110 VAC receptacle J230. (5) Connect negative (-) probe of multimeter to supply socket of 110 VAC receptacle J230 and note reading on multimeter. (6) Connect positive (+) probe of multimeter to neutral pole of 110 VAC receptacle J230. (7) Connect negative (-) probe of multimeter to neutral socket of 110 VAC receptacle J230 and note reading on multimeter. (8) Connect positive (+) probe of multimeter to ground pole of 110 VAC receptacle J230. (9) Connect negative (-) probe of multimeter to ground socket of 110 VAC receptacle J230 and note reading on multimeter. (10) If continuity is not present in steps (5), (7), and (9), replace 110 VAC receptacle J230 (para 16-53).