NO TM 9-2320-365-20-2 2-1208 Change 1 e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). AC power connected (TM 9-2320-365-10). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Personnel Required (2) References TM 9-4910-571-12&P START 1. KNOWN INFO TEST OPTIONS Operational Test REASON FOR QUESTION YES Go to step 5 of this fault. This question eliminates possible problems and determines where troubleshooting continues. Does 110 VAC outlet J235 operate? POSSIBLE PROBLEMS 110 VAC outlets J231, J232, J233, and J234 OK. Faulty circuit breaker CB9. Faulty wire 701C. Faulty wire 702C. Faulty relay K35. Faulty 110 VAC receptacle J230. Faulty wire 1499D. Faulty wire 3085J. Faulty wire 3085AC.