TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 146 of 1432
TM 9-2320-365-20-2 2-1200 Change 1 4. TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION KNOWN INFO 110 VAC outlets J230, J232, J233, and J235 OK. 110 VAC outlet J234 OK. Circuit breaker CB7 OK. Wire 701B OK. Wire 702B OK. Relay K35 OK. 110 VAC receptacle J231 OK. Wire 1499C OK. POSSIBLE PROBLEMS Faulty wire 3085M. Faulty wire 3085AB. Is continuity present on wire 3085M from 110 VAC receptacle J231 to terminal board TB3? If continuity is not present, wire 3085M is faulty. If continuity is present, wire 3085AB is faulty. Repair or replace wire 3085AB (para 2-40). YES Repair or replace wire 3085M (para 2-40). NO e110. M1079 110 VAC OUTLET J231 DOES NOT OPERATE (CONT)