NO e108. M1079 110 VAC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE (CONT) TM 9-2320-365-20-2 2-1188 Change 1 7. KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION POSSIBLE PROBLEMS Fluorescent lights OK. Circuit breaker CB5 OK. Wire 701A OK. Faulty wire 702A. Faulty relay K35. Is continuity present on wire 702A from K35 relay base terminal 4 to supply pole of 110 VAC receptacle J232? If continuity is not present, wire 702A is faulty. If continuity is present, relay K35 is faulty. Repair or replace wire 702A (para 2-40). YES Replace relay K35 (para 16-62).