TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 126 of 1432
e108. M1079 110 VAC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE (CONT) TM 9-2320-365-20-2 2-1180 Change 1 3. KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION Fluorescent lights OK. 110 VAC outlet J233 OK. 110 VAC receptacle J232 OK. POSSIBLE PROBLEMS Faulty wire 1499B. Faulty wire 3085K. Faulty wire 3085AA. Is continuity present on wire 1499B from 110/208 VAC POWER DISTRIBUTION PANEL to 110 VAC receptacle J232? If continuity is not present, wire 1499B is faulty. NO Repair or replace wire 1499B (para 2-40). YES