Change 1 2-1179 TM 9-2320-365-20-2 (1) Open door on 110/208 VAC POWER DISTRIBUTION PANEL (TM 9-2320-365- 10). (2) Position circuit breaker CB1 to OFF (TM 9-2320-365-10). (3) Remove screw and cover from 110 VAC outlet J232. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to supply pole of 110 VAC receptacle J232. (6) Connect negative (-) probe of multimeter to supply socket of 110 VAC receptacle J232 and note reading on multimeter. (7) Connect positive (+) probe of multimeter to neutral pole of 110 VAC receptacle J232. (8) Connect negative (-) probe of multimeter to neutral socket of 110 VAC receptacle J232 and note reading on multimeter. (9) Connect positive (+) probe of multimeter to ground pole of 110 VAC receptacle J232. CONTINUITY TEST (10) Connect negative (-) probe of multimeter to ground socket of 110 VAC receptacle J232 and note reading on multimeter. (11) If continuity is not present in steps (6), (8), and (10), replace 110 VAC receptacle J232 (para 16-53).