TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 122 of 1432

YES e108. M1079 110 VDC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE TM 9-2320-365-20-2 2-1176 Change 1 INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Personnel Required (2) References TM 9-4910-571-12&P START 1. KNOWN INFO TEST OPTIONS Operational Test REASON FOR QUESTION POSSIBLE PROBLEMS Fluorescent lights OK. Faulty 110 VAC receptacle J232. Faulty wire 1499B. Faulty wire 3085K. Faulty wire 3085AA. Faulty circuit breaker CB5. Faulty wire 701A. Faulty wire 702A. Faulty relay K35. Does 110 VAC outlet J233 operate? This question eliminates possible problems and determines where troubleshooting continues. NO Go to step 5 of this fault.