TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 121 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1175 2-1175 2-1175 2-1175 2-1175 CONTINUITY TEST (1) Loosen screw in terminal board TB3. (2) Remove wire 3085G from terminal board TB3. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to wire 3085G. (5) Connect negative (-) probe of multimeter to ground socket of 110 vac receptacle J235 and note multimeter. (6) If continuity is not present, repair or replace wire 3085G (para 2-40). (7) If continuity is present, repair or replace wire 3085AG (para 2-40). (8) Position wire 3085G on terminal board TB3. (9) Tighten screw in terminal board TB3. (10) Position wire 1499F on terminal board TB4. (11) Tighten screw in terminal board TB4. (12) Install cover on 110/208 VAC POWER DISTRIBUTION PANEL with six screws. (13) Install cover on 110 vac outlet J235 with screw.