TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1174 2-1174 2-1174 2-1174 2-1174 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 NO YES POSSIBLE PROBLEMS 4. 110 vac outlet J230 OK. 110 vac receptacle J235 OK. Wire 702F OK. Wire 1499F OK. If continuity is not present, wire 3085G is faulty. If continuity is present, wire 3085AG is faulty. Faulty wire 3085G. Faulty wire 3085AG. Is continuity present on wire 3085G from 110 vac receptacle J235 to terminal board TB3? Repair or replace wire 3085AG (para 2-40). Repair or replace wire 3085G (para 2-40). e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT)