TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 118 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1172 2-1172 2-1172 2-1172 2-1172 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 NO YES POSSIBLE PROBLEMS 3. 110 vac outlet J230 OK. 110 vac receptacle J235 OK. Wire 702F OK. Faulty wire 1499F. Faulty wire 3085G. Faulty wire 3085AG. Is continuity present on wire 1499F from 110 vac receptacle J235 to terminal board TB4? Repair or replace wire 1499F (para 2-40). If continuity is not present, wire 1499F is faulty. e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT) e107. M1079 110 VAC OULET J235 DOES NOT OPERATE (CONT)