TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1165 of 1432

WARNING TM 9-2320-365-20-2 Change 1 2-2118.7/(2-2118.8 Blank) Drop hydraulic pressure to zero before disconnecting any hydraulic hoses. Failure to comply may result in injury to personnel. Hydraulic fluid (MIL-H-5606) is TOXIC. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come into contact with hydraulic fluid should be washed immediately. Saturated clothing should be removed immediately. Failure to comply may result in injury to personnel. Compressed air used for cleaning purposes will not exceed 30 psi (270 kPa). Use only with effective chip guarding and personal protective equipment (goggles, shields, gloves, etc.). Failure to comply may result in injury to personnel. NOTE (1) Remove pin from hydraulic manifold cover and lower cover. (2) Cycle FUNCTION SELECT knob through all settings. (3) Cycle SPARE TIRE knob through both selector settings. (4) Remove screw, knob, and SPARE TIRE valve from hydraulic manifold. (5) Remove orifice filter (if equipped) from hydraulic manifold. (6) If debris is present in orifice filter, replace orifice filter. (7) Remove orifice screw from hydraulic manifold. (8) If debris is present in orifice screw, clean orifice screw with compressed air. NOTE If no orifice filter was previously installed, install orifice filter at this time. (9) Install orifice screw and orifice filter in hydraulic manifold. (10) Position SPARE TIRE valve and knob on hydraulic manifold with screw. (11) Tighten screw to 5-15 lb-in. (1-2 N·m). Cont. on page 2-2118.9. Perform steps (1) through (11) on hydraulic manifolds P/N HFC32598.