TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 115 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1169 2-1169 2-1169 2-1169 2-1169 CONTINUITY TEST (1) Remove screw and cover from 110 vac outlet J235. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to supply pole of 110 vac receptacle J235. (4) Connect negative (-) probe of multimeter to supply socket of 110 vac receptacle J235 and note reading on multimeter. (5) Connect positive (+) probe of multimeter to neutral pole of 110 vac receptacle J235. (6) Connect negative (-) probe of multimeter to neutral socket of 110 vac receptacle J235 and note reading on multimeter. (7) Connect positive (+) probe of multimeter to ground pole of 110 vac receptacle J235. (8) Connect negative (-) probe of multimeter to ground socket of 110 vac receptacle J235 and note reading on multimeter. (9) If continuity is not present in steps (4), (6), and (8), replace 110 vac receptacle J235 (para 16-53).