TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2109 2-2109 2-2109 2-2109 2-2109 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to winch remote control cable socket A. (3) Connect negative (-) probe of multimeter to winch remote control cable socket C. (4) Position winch remote control switch to in and note reading on multimeter. (5) If continuity is not present, replace winch remote control cable. (6) If continuity is present, replace LMHC winch assembly (para 20-70). (7) Connect winch remote control cable to winch remote control connector. (8) Install cover on base plate with 18 screws. (1) Disconnect winch remote control cable from winch remote control connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to left middle post of in solenoid. (4) Connect negative (-) probe of multimeter to winch remote control connector pin C and note reading on multimeter. (5) If continuity is not present, replace power harness (para 20-70).