TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2105 2-2105 2-2105 2-2105 2-2105 CONTINUITY TEST CONTINUITY TEST (1) Disconnect winch remote control cable from winch remote control connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to top middle post of in solenoid. (4) Connect negative (-) probe of multimeter to winch remote control connector pin A and note reading on multimeter. (5) If continuity is not present, replace power harness (para 20-70). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to winch remote control cable connector socket A. (3) Connect negative (-) probe of multimeter to winch remote control cable connector socket B. (4) Position winch remote control switch to OUT and note reading on multimeter. (5) Connect positive (+) probe of multimeter to winch remote control cable connector socket A. (6) Connect negative (-) probe of multimeter to winch remote control cable connector socket C. (7) Position winch remote control switch to in and note reading on multimeter. (8) If continuity is not present, replace winch remote control cable. (9) If continuity is present, replace LMHC winch assembly (para 20-70). (10) Connect LMHC control power cable to LMHC winch assembly power connector. (11) Connect winch remote control cable to winch remote control connector. (12) Install cover on base plate with 18 screws.