TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1131 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2103 2-2103 2-2103 2-2103 2-2103 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to left top post of in solenoid. (3) Connect negative (-) probe of multimeter to left bottom post of in solenoid and note reading on multimeter. (4) If continuity is not present, replace in solenoid (para 20-70). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to left bottom post of in solenoid. (3) Connect negative (-) probe of multimeter to winch assembly bottom terminal lug and note reading on multimeter. (4) If continuity is not present, replace power harness (para 20-70).