TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2099 2-2099 2-2099 2-2099 2-2099 CONTINUITY TEST CONTINUITY TEST (1) Remove 18 screws and cover from base plate. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to power harness connector pin A. (4) Connect negative (-) probe of multimeter to top post of out solenoid and note reading on multimeter. (5) If continuity is not present, replace power harness (para 20-70). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to top right post of out solenoid. (3) Connect negative (-) probe of multimeter to bottom right post of out solenoid and note reading on multimeter. (4) If continuity is not present, replace out solenoid (para 20-70).