TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1125 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2097 2-2097 2-2097 2-2097 2-2097 CONTINUITY TEST (1) Disconnect LMHC control power cable from LMHC winch assembly power connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to one end of LMHC control box power cable socket A. (4) Connect negative (-) probe of multimeter to other end of LMHC control box power cable socket A and note reading on multimeter. (5) If continuity is not present, replace LMHC control box power cable. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to LMHC control box power cable socket B. (4) Connect negative (-) probe of multimeter to LMHC control box power cable socket B and note reading on multimeter. (5) If continuity is not present, replace LMHC control box power cable. CONTINUITY TEST