TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1121 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2093 2-2093 2-2093 2-2093 2-2093 CONTINUITY TEST CONTINUITY TEST (1) Open cover on LMHC control box. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to NATO plug positive (+) terminal. (4) Connect negative (-) probe of multimeter to LMHC control box circuit breaker supply post and note reading on multimeter. (5) If continuity is not present, replace wire 170 (para 20-63). (1) Disconnect LMHC control box power cable from LMHC control box connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to NATO plug negative (-) terminal. (4) Connect negative (-) probe of multimeter to LMHC control box connector pin B and note reading on multimeter. (5) If continuity is not present, replace wire 150 (para 20-63). (6) Install cover and retainer on NATO plug with eight screws.