TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1121 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-2093 2-2093 2-2093 2-2093 2-2093  CONTINUITY TEST  CONTINUITY TEST  (1) Open cover on LMHC control box.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  NATO plug positive (+) terminal.  (4) Connect negative (-) probe of multimeter to  LMHC control box circuit breaker supply post  and note reading on multimeter.  (5) If continuity is not present, replace wire 170  (para 20-63).  (1) Disconnect LMHC control box power cable  from LMHC control box connector.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  NATO plug negative (-) terminal.  (4) Connect negative (-) probe of multimeter to  LMHC control box connector pin B and note  reading on multimeter.  (5) If continuity is not present, replace wire 150  (para 20-63).  (6) Install cover and retainer on NATO plug with  eight screws.