TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1111 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2083 2-2083 2-2083 2-2083 2-2083 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P921-C. (3) Connect negative (-) probe of multimeter to connector J39-1 and note reading on multimeter. (4) If continuity is not present, repair wire 3028 (para 2-40) or replace troop transport alarm cable assembly (para 20-79). (5) Connect connector P921 to connector J921. (1) Set multimeter to ohms. (2) Disconnect connector clamp from connector J39. (3) Disconnect connector J39 from connector P39. (4) Connect positive (+) probe of multimeter to connector P921-A. (5) Connect negative (-) probe of multimeter to connector J39-2 and note reading on multimeter. (6) If continuity is not present, repair wire 32 (para 2-40) or replace troop transport alarm cable assembly (para 20-79).