TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1109 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2081 2-2081 2-2081 2-2081 2-2081 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal lug TL164. (3) Connect negative (-) probe of multimeter to connector J921-A and note reading on multimeter. (4) If continuity is not present, repair wire 32 (para 2-43) or replace troop transport alarm switch connector (para 20-80). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal lug TL165. (3) Connect negative (-) probe of multimeter to connector J921-C and note reading on multimeter. (4) If continuity is not present, repair wire 3028 (para 2-43) or replace troop transport alarm switch connector (para 20-80).