TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1107 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-2079 2-2079 2-2079 2-2079 2-2079 CONTINUITY TEST (1) Disconnect connector P921 from connector J921. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to pin 1 of troop transport alarm switch. (4) Connect negative (-) probe of multimeter to pin 2 of troop transport alarm switch. (5) Press troop transport alarm switch and note reading on multimeter. (6) If continuity is not present, replace troop transport alarm switch (para 20-80).