TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1102 of 1432

TEST OPTIONS YES NO REASON FOR QUESTION 2. Continuity Test or STE/ICE-R Test #91 TEST OPTIONS 2-2012 Change 2 Replace circuit breaker CB10 (para 20-87). u7. NO POWER TO MOBILE TRACKING SYSTEM (MTS) (CONT) Is continuity present through circuit breaker CB10? Perform Special Purpose Kit Troubleshooting task u1. No Power to Digitization Rack. POSSIBLE PROBLEMS Faulty circuit breaker CB10. Faulty digitization rack power supply. Circuit breaker CB10 is not tripped. If continuity is not present, circuit breaker CB10 is faulty. If continuity is present, perform Special Purpose Kits Troubleshooting task u1. No Power to Digitization Rack. TM 9-2320-365-20-2