TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1100 of 1432
1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. Contact supervisor, Mobile Tracking System (MTS) troubleshooting needs to be performed. Is 24 VDC present at terminal lug TL1? u7. NO POWER TO MOBILE TRACKING SYSTEM (MTS) INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10) Materials/Parts Ties, Cable, Plastic (Item 76, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 44, Appendix C) Personnel Required (2) 2-2010 Change 2 START TM 9-2320-365-20-2 If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Mobile Tracking System (MTS) troubleshooting. Faulty circuit breaker CB10. Faulty digitization rack power supply. Faulty Mobile Tracking System (MTS). POSSIBLE PROBLEMS Circuit breaker CB10 is not tripped.