TEST OPTIONS YES NO REASON FOR QUESTION 2. Continuity Test or STE/ICE-R Test #91 TEST OPTIONS 2-2008 Change 2 TM 9-2320-365-20-2 Circuit breaker CB8 is not tripped. POSSIBLE PROBLEMS Faulty circuit breaker CB8. Faulty digitization rack power supply. Is continuity present through circuit breaker CB8? If continuity is not present, circuit breaker CB8 is faulty. If continuity is present, perform Special Purpose Kits Troubleshooting task u1. No Power to Digitization Rack. Perform Special Purpose Kit Troubleshooting task u1. No Power to Digitization Rack. Replace circuit breaker CB8 (para 20-87). u6. NO POWER TO SINGLE CHANNEL GROUND & AIRBORNE RADIO (SINCGAR)/FORCE XXI BATTLE COMMAND BRIGADE OR BELOW (FBCB) (CONT)