TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1096 of 1432
1.  WARNING  Read WARNING  on following page.  TEST OPTIONS  Voltage Test or  STE/ICE-R Test #89  YES  NO  TEST OPTIONS  REASON FOR QUESTION  Go to step 2 of this fault.  Contact supervisor, SINGGAR/Force  XXI Battle Command Brigade or Below (FBCB)  troubleshooting needs to be performed.  Tools/Special Tools  Multimeter, Digital (Item 22, Appendix C)  Tool Kit, Genl Mech (Item 44, Appendix C)  Personnel Required  (2)  2-2006 Change 2  START  POSSIBLE PROBLEMS  Circuit breaker CB8 is not  tripped.  Is 24 VDC present at  terminal lug TL2?  TM 9-2320-365-20-2  u6. NO POWER TO SINGLE CHANNEL GROUND & AIRBORNE RADIO (SINCGAR)/FORCE XXI  BATTLE COMMAND BRIGADE OR BELOW (FBCB)  INITIAL SETUP  Equipment Conditions  Engine shut down (TM 9-2320-365-10)  Materials/Parts  Ties, Cable, Plastic (Item 76, Appendix D)  Faulty circuit breaker CB8.  Faulty digitization rack power  supply.  Faulty SINCGAR/FBCB.  If 24 VDC is not present, go to  step 2 of this fault. If 24 VDC  is present, perform SINCGAR/  FBCB troubleshooting.