1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 YES NO TEST OPTIONS REASON FOR QUESTION Go to step 2 of this fault. u5. NO POWER TO DRIVER VISUAL ENHANCEMENT (DVE) 2-2002 Change 2 INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10) Materials/Parts Ties, Cable, Plastic (Item 76, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 44, Appendix C) Personnel Required (2) START TM 9-2320-365-20-2 POSSIBLE PROBLEMS Circuit breaker CB6 is not tripped. Faulty circuit breaker CB6. Faulty digitization rack power supply. Faulty Driver Visual Enhancement (DVE) system. Is 24 VDC present at terminal lug TL3? If 24 VDC is not present, go to step 2 of this fault. If 24 VDC is present, perform Driver Visual Enhancement (DVE) troubleshooting. Contact supervisor, Driver Visual Enhancement (DVE) troubleshooting needs to be performed.