TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1083 of 1432
VOLTAGE TEST  WARNING  Remove rings, bracelets, watches, necklaces,  and any other jewelry before working around  vehicle. Jewelry can catch on equipment and  cause injury or short across electrical circuits  and cause severe burns or electrical shock.  Change 2 2-1993  (1) Remove dust boot from terminal lug TL15.  (2) Set multimeter to volts DC.  (3) Connect positive (+) probe of multimeter to  terminal lug TL15.  (4) Connect negative (-) probe of multimeter to  known good ground.  (5) Position master power switch to on  (TM 9-2320-365-10) and note reading on  multimeter.  (6) Position master power switch to off  (TM 9-2320-365-10).  (7) If 24 VDC is not present, replace power  cable from terminal lug TL15 to terminal  lug TL22 (para 20-88).  (8) If 24 VDC is present, replace Power  Distribution Panel (PD2) (para 20-88).  TM 9-2320-365-20-2