CONTINUITY TEST  Change 2 2-1987  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  terminal lug TL18.  (3) Connect negative (-) probe of multimeter to  a known good ground and note reading on  multimeter.  (4) If continuity is not present, replace power  cable from terminal lug TL18 to terminal  board TB2 (para 20-88).  (5) If continuity is present, replace Power  Distribution Panel (PD1) (para 20-88).  TM 9-2320-365-20-2