NOTE Change 2 2-1981 (1) Remove three screws and washers from Power Distribution Panel (PDP). (2) Remove three screws from Power Distribution Panel (PDP). (3) Lift Power Distribution Panel (PDP) to gain access. (4) Push in reset button on circuit breaker CB11 to see if it is tripped. (5) If circuit breaker CB11 is not tripped, go to step 3 of this fault. (6) If circuit breaker CB11 trips agian, replace circuit breaker CB11 (para 20-88). Perform steps (7) through (9) if circuit breaker CB11 is faulty. (7) Position electrical distribution block cover on power distribution shelf. (8) Tighten wing screw on electrical distribution block cover. (9) Install wing screw in power distribution shelf. TM 9-2320-365-20-2