TEST OPTIONS REASON FOR QUESTION YES NO TEST OPTIONS POSSIBLE PROBLEMS Nothing. 2. Is circuit breaker CB11 tripped? Visual Inspection Go to step 3 of this fault. u1. NO POWER TO DIGITIZATION RACK (CONT) 2-1980 Change 2 Reset circuit breaker CB11. If circuit breaker CB11, trips agian replace circuit breaker CB11 (para 20-88). Circuit breaker CB11 tripped. Faulty circuit breaker CB11. Faulty power cable from terminal lug TL24 to terminal lug TL20. Faulty power cable from terminal lug TL23 to terminal lug TL16. If circuit breaker CB11 is tripped, digitization rack will not have power. TM 9-2320-365-20-2