TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1068 of 1432
TEST OPTIONS POSSIBLE PROBLEMS Nothing. 1. WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where troubleshooting continues. YES NO Go to step 2 of this fault. Go to step 5 of this fault. INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10) Materials/Parts Ties, Cable, Plastic (Item 76, Appendix D) Tools/Special Tools Multimeter, Digital (Item 22, Appendix C) Tool Kit, Genl Mech (Item 44, Appendix C) Personnel Required (2) 2-1978 Change 2 u1. NO POWER TO DIGITIZATION RACK START Circuit breaker CB11 tripped. Faulty circuit breaker CB11. Faulty power cable from terminal lug TL24 to terminal lug TL20. Faulty power cable from terminal lug TL23 to terminal lug TL16. Faulty power cable from terminal lug TL18 to terminal block TB2. Faulty Power Distribution Panel (PD1). Is 24 VDC present at terminal lug TL16? TM 9-2320-365-20-2