TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1160 2-1160 2-1160 2-1160 2-1160 1. START YES NO TEST OPTIONS KNOWN INFO INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). AC power disconnected (TM 9-2320-365-10). Personnel Required (2) e106. M1079 110 VAC OUTLET J234 DOES NOT OPERATE Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P 110 vac outlet J231 OK. POSSIBLE PROBLEMS Faulty 110 vac receptacle J234. Faulty wire 702E. Faulty wire 1499E. Faulty wire 3085H. Faulty wire 3085AE. Is continuity present across 110 vac receptacle J234? Replace 110 vac receptacle J234 (para 16-53). Continuity Test or STE/ICE-R #91 REASON FOR QUESTION If continuity is not present, 110 vac receptacle J234 is faulty.