KNOWN INFO TEST OPTIONS YES REASON FOR QUESTION Pressure Test or STE/ICE-R Test #51 NO If 2,500-4,000 psi (17,238- 27,580 kPa) is present, hydraulic hose 513 is faulty. 6. Go to step 7 of this fault. Other hydraulic manifold functions OK. Hydraulic hoses free from leaks. Hydraulic hoses 508 and 510 OK. Suspension compression tee fitting OK. Air/hydraulic manifold OK. Hydraulic hose 512 OK. POSSIBLE PROBLEMS Faulty hydraulic hose 513. Faulty suspension release tee fitting. Faulty suspension cylinder(s). Faulty hydraulic hose(s) 509 and/or 511. Is 2,500-4,000 psi (17,238-27,580 kPa) present at suspension release tee fitting output port? Replace hydraulic hose 513 (para 19-11). TM 9-2320-365-20-2 2-1970.10 Change 1 t2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)