TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1033 of 1432
PRESSURE TEST (1) Position drain pan under air/hydraulic manifold (2) Disconnect hydraulic hose 512 from SUSP COMPRESS port. (3) Connect STE/ICE-R between hydraulic hose 512 and SUSP COMPRESS port. (4) Start engine (TM 9-2320-365-10). (5) Position SUSPENSION knob to RAISE (TM 9-2320-365-10). (6) Position FUNCTION SELECT knob to SUSPENSION (TM 9-2320-365-10). (7) Push and hold PUMP plunger button (TM 9-2320-365-10) and perform STE/ICE-R Test #51. (8) If 2,500-4,000 psi (17,238-27,580 kPa) is not present, repair or replace air/hydraulic manifold (para 19-4). (9) If 2,500-4,000 psi (17,238-27,580 kPa) is present, replace hydraulic hose 512 (para 19-11). (10) Disconnect STE/ICE-R from hydraulic hose 512 and SUSP COMPRESS port. (11) Connect hydraulic hose 512 to SUSP COMPRESS port. Change 1 2-1970.9 TM 9-2320-365-20-2