TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1032 of 1432
KNOWN INFO TEST OPTIONS YES REASON FOR QUESTION Pressure Test or STE/ICE-R Test #51 NO Is 2,500-4,000 psi (17,238-27,580 kPa) present at SUSP COMPRESS output port? If 2,500-4,000 psi (17,238- 27,580 kPa) is not present, air/hydraulic manifold is faulty. If 2,500-4,000 psi (17,238- 27,580 kPa) is present, hydraulic hose 512 is faulty. 5. Other hydraulic manifold functions OK. Hydraulic hoses free from leaks. Hydraulic hoses 508 and 510 OK. Suspension compression tee fitting OK. Hydraulic hose 513 OK. Suspension release tee fitting OK. Suspension cylinders OK. Hydraulic hoses 509 and 511 OK. POSSIBLE PROBLEMS Faulty air/hydraulic manifold. Faulty hydraulic hose 512. Repair or replace air/hydraulic manifold (para 19-4). Replace hydraulic hose 512 (para 19-11). TM 9-2320-365-20-2 2-1970.8 Change 1 t2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)