TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1025 of 1432
PRESSURE TEST NOTE SYSTEM PARK control must be engaged (TM 9-2320-365-10) before operating SUSPENSION compression. (1) Position drain pan under RH suspension cylinder. (2) Disconnect hydraulic hose 508 from RH suspension cylinder input port. (3) Connect STE/ICE-R between hydraulic hose 508 and RH suspension cylinder input port. (4) Start engine (TM 9-2320-365-10). (5) Position FUNCTION SELECT knob to SUSPENSION (TM 9-2320-365-10). (6) Push and hold PUMP plunger button (TM 9-2320-365-10) and perform STE/ICE-R Test #51. (7) Shut down engine (TM 9-2320-365-10). (8) Disconnect STE/ICE-R from RH suspension cylinder input port and hydraulic hose 508. (9) Connect hydraulic hose 508 to RH suspension cylinder input port. (10) Repeat steps (1) through (9) on LH suspension cylinder and hydraulic hose 510. (11) If 2,500-4,000 psi (17,238-27,580 kPa) is not present at either suspension cylinder, go to step 3 of this fault. Change 1 2-1970.1 TM 9-2320-365-20-2 WARNING Drop hydraulic pressure to zero before disconnecting any hydraulic hoses. Failure to comply may result in injury to personnel. Hydraulic oil (MIL-H 5605) is TOXIC. Wear protective goggles and gloves. Use only in well ventilated area. Avoid contract with skin, eyes, and clothes. Skin and clothing that come into contact with hydraulic oil should be washed immediately. Failure to comply may result in injury to personnel.