KNOWN INFO  YES  NO  14.  Is 2,500-4,000 psi  (17,238-27,580 kPa)  present at back-up hydraulic  pump output port?  Replace back-up  hydraulic pump (para 19-2).  Hydraulic hoses free from  leaks.  Air/hydraulic manifold filters  OK.  Hydraulic hose 515 OK.  Air/hydraulic power unit OK.  Air hose 507 OK.  Secondary air tank inversion  valve OK.  Air hose 502 OK.  Air hose 514 OK.  Hydraulic hose 520 OK.  Air/hydraulic manifold OK.  POSSIBLE PROBLEMS  Faulty back-up hydraulic pump.  Faulty hydraulic hose 521.  Replace hydraulic hose  521 (para 19-11).  TEST OPTIONS  Pressure Test or  STE/ICE-R Test #51  REASON FOR QUESTION  If 2,500-4,000 psi (17,238-  27,580 kPa) is not present,  back-up hydraulic pump is  faulty. If 2,500-4,000 psi  (17,238-27,580 kPa) is  present, hydraulic hose 521 is  faulty.  TM 9-2320-365-20-2  2-1968.16 Change 1  t1. CAB TILT, SPARE TIRE RETAINER, AND SUSPENSION COMPRESSION DO  NOT OPERATE (CONT)