TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1017 of 1432
PRESSURE TEST (1) Position drain pan under back-up hydraulic pump. (2) Disconnect hydraulic hose 520 from back-up hydraulic pump return port. (3) Connect STE/ICE-R between hydraulic hose 520 and return port. (4) Start engine (TM 9-2320-365-10). (5) Position SUSPENSION knob to LOWER (TM 9-2320-365-10). (6) Position FUNCTION SELECT knob to SUSPENSION (TM 9-2320-365-10). (7) Push and hold PUMP plunger button (TM 9-2320-365-10) and perform STE/ICE-R Test #51. (8) If 2,500-4,000 psi (17,238-27,580 kPa) is not present, go to step 15 of this fault. (9) Disconnect STE/ICE-R from hydraulic hose 520 and return port. (10) Connect hydraulic hose 520 to return port. Change 1 2-1968.13 TM 9-2320-365-20-2