TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1013 of 1432
WARNING Drop hydraulic pressure to zero before disconnecting any hydraulic hoses. Failure to comply may result in injury to personnel. Hydraulic fluid (MIL-H-5606) is TOXIC. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come into contact with hydraulic fluid should be washed immediately. Saturated clothing should be removed immediately. Failure to comply may result in injury to personnel. Compressed air used for cleaning purposes will not exceed 30 psi (270 kPa). Use only with effective chip guarding and personal protective equipment (goggles, shields, gloves, etc.). Failure to comply may result in injury to personnel. TM 9-2320-365-20-2 Change 1 2-1968.9 (1) Remove two plugs from air/hydraulic manifold. Discard plugs. (2) Remove two retainers, filters, and springs from air/hydraulic manifold. Discard retainers and springs. (3) Inspect filters for debris or signs of damage. (4) Discard filters. (5) If filters are free from debris and damage, repair or replace air/hydraulic manifold (para 19-4). (6) Position two springs and filters in hydraulic manifold with two retainers. (7) Install two preformed packings on plugs. (8) Install two plugs in air/hydraulic manifold.