TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1011 of 1432

(1) Drain air tanks (TM 9-2320-365-10). (2) Loosen air hose 502 at secondary air tank inversion valve delivery port. (3) Start engine and charge air tanks (TM 9-2320-365-10). (4) Check for presence of air at secondary air tank inversion valve delivery port. (5) If air is not present, replace secondary air tank inversion valve (para 23-4). (6) If air is present, replace air hose 502 (para 23-3). (7) Drain air tanks (TM 9-2320-365-10). (8) Tighten air hose 502 at secondary air tank inversion valve delivery port. Change 1 2-1968.7 TM 9-2320-365-20-2