TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 1007 of 1432

(1) Drain air tanks (TM 9-2320-365-10). (2) Loosen air hose 507 at PUMP CYL port. (3) Start engine and charge air tanks (TM 9-2320-365-10). (4) Check for presence of air at PUMP CYL port. (5) If air is not present, go to step 8 of this fault. (6) If air is present, replace air hose 507 (para 23-3). (7) Drain air tanks (TM 9-2320-365-10). (8) Tighten air hose 507 at PUMP CYL port. Change 1 2-1968.3 TM 9-2320-365-20-2