TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1005 of 1432
(1) Drain air tanks (TM 9-2320-365-10). (2) Loosen air hose 507 at air/hydraulic power unit. (3) Start engine and charge air tanks (TM 9-2320-365-10). (4) Check for presence of air at air hose 507. (5) If air is not present, go to step 7 of this fault. (6) If air is present, replace air/hydraulic power unit (para 19-3). (7) Drain air tanks (TM 9-2320-365-10). (8) Tighten air hose 507 at air/hydraulic power unit. Change 1 2-1968.1 TM 9-2320-365-20-2