TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 1000 of 1432
KNOWN INFO  NO  YES  4.  Is 2,500-4,000 psi  (17,238-27,580 kPa)  present at port P1?  Replace air/hydraulic  manifold (para 19-4).  Go to step 5  of this fault.  Hydraulic hoses free from  leaks.  Air/hydraulic manifold filters  OK.  Hydraulic hose 514 OK.  Back-up hydraulic pump OK.  Hydraulic hose 521 OK.  Hydraulic hose 520 OK.  POSSIBLE PROBLEMS  Faulty hydraulic hose 515.  Faulty air/hydraulic power unit.  Faulty air hose 507.  Faulty secondary air tank  inversion valve.  Faulty air hose 502.  Faulty air/hydraulic manifold.  TEST OPTIONS  Pressure Test or  STE/ICE-R Test #51  REASON FOR QUESTION  If 2,500-4,000 psi (17,238-  27,580 kPa) is present,  air/hydraulic manifold is faulty.  TM 9-2320-365-20-2  2-1964 Change 1  t1. CAB TILT, SPARE TIRE RETAINER, AND SUSPENSION COMPRESSION DO  NOT OPERATE (CONT)