TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 975 of 1760

VOLTAGE TEST WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. (1) Set multimeter to volts DC. (2) Connect positive (+) probe of multimeter to relay K20 terminal 86 on PDP. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If 12 VDC is not present, go to step 15 of this fault. Change 1 2-594.15 TM 9-2320-365-20-1