TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 947 of 1760
CONTINUITY TEST (1) Disconnect batteries (para 7-48). (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to relay K20 terminal 85 on PDP. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, repair wire 3054 from relay K20 terminal 85 on PDP to terminal board TB2 position 44 on PDP (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) If continuity is present, replace relay K20 (para 7-9). (7) Install relay K20 in PDP. (8) Install PDP cover (para 16-2). Change 1 2-584.61 TM 9-2320-365-20-1