TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 941 of 1760
CONTINUITY TEST (1) Disconnect batteries (para 7-48). (2) Remove relay K20 from PDP. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to circuit breaker CB67 socket 3 on PDP. (5) Connect negative (-) probe of multimeter to relay K20 terminal 87 on PDP and note reading on multimeter. (6) If 12 VDC is not present, repair wire 1914 from circuit breaker CB67 socket 3 to relay K20 terminal 87 on PDP (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (7) Install circuit breaker CB67 in PDP. (8) Connect batteries (para 7-48). Change 1 2-584.55 TM 9-2320-365-20-1