TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 859 of 1760

CONTINUITY TEST CAUTION (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P3 pin 2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3097 (para 2-40) from connector P3 pin 2 to terminal lug TL86 or replace M1081 cab clearance and marker lights lower cable assembly (para 7-55). NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. Change 1 2-573 TM 9-2320-365-20-1