TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-539 2-539 2-539 2-539 2-539 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to lamp socket. (3) Connect negative (-) probe of multimeter to composite front light housing and note reading on multimeter. (4) If continuity is not present, replace composite front light assembly (para 7-33). (5) If continuity is present, repair wire 3091 (para 2-40) or replace front lights cable assembly (para 7-74). (6) Install lamp in socket. (7) Install preformed packing and cover on housing with five screws. (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector PX15 from main light switch. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to main light switch terminal L. (5) Connect negative (-) probe of multimeter to main light switch terminal F. (6) Position main light switch auxiliary lever to PARK (TM 9-2320-365-10) and note reading on multimeter. (7) If continuity is not present, replace main light switch (para 7-17). (8) If continuity is present, repair wire 491 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (9) Connect connector PX15 to main light switch. (10) Install instrument panel assembly (para 7-15).