TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-523 2-523 2-523 2-523 2-523 CONTINUITY TEST CONTINUITY TEST (1) Remove PDP cover (para 16-2). (2) Remove relay K8 from PDP. (3) Disconnect connector P12 (RH) or connector P4 (LH) from housing. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector P12 (RH) or connector P4 (LH). (6) Connect negative (-) probe of multimeter to PDP, terminal 87A, where relay K8 was removed and note reading on multimeter. (7) If continuity is not present, go to step 5 of this fault. (8) Connect connector P12 (RH) or connector P5 (LH) to housing. (1) Set multimeter to ohms (2) Connect positive (+) probe of multimeter to relay K8 terminal 87A. (3) Connect negative (-) probe of multimeter to relay K8 terminal 30 and note reading on multimeter. (4) If continuity is not present, replace relay K8 (para 7-9). (5) If continuity is present, replace turn signal switch (para 7-25). (6) Install relay K8 in PDP. (7) Install PDP cover (para 16-2).